Selling Cooler Accessories and Parts at Tajik Spare Conditioning Shop
Sale of cooler accessories and parts of our specialized service, including a variety of gas spare boards, chol door spare compressors and splits, Duct Spare Spare Remote, Multi -Verious and VRF spare board and other air conditioners and other parts of the air conditioner Many more of these pieces.
Each air conditioner is made of mechanical parts next to the electrical sections. Mechanical components form the overall structure of the air conditioner cooling system, and the electrical components are present in the system to control and manage these mechanical parts. The components with mechanical function in the interior parts of the air conditioner are as follows:
Cooler compressor
The compressor is the main internal components of the air conditioner and is a heart of the cooling system. This section is actually a type of refrigerant gas cycle pump. The refrigerant fluid pressure inside the compressor has increased to send it to other parts of the system to a pumping mode for thermal exchange. The interior parts of the air conditioner include the motor and pumping section.
Optimal compressor performance is effective in slow, low -consumption performance with proper efficiency of the air conditioner. At the same time, the reason for the work of the air conditioner is also in the long run of the same compressor. The compressor itself only contains several mechanical and electrical compressors. Together, these components have formed a set of gas pumping gas cooler cooling system.
Evaporator in the Split of Gas Cooler
The evaporator is the heat exchange system in the air conditioner. What comes out of the air cooler as cool air is actually a continuous heat exchange that flows into the evaporator system. This section is a long pipeline for refrigerant fluid passage. The refrigerant fluid has been significantly cooled before entering the evaporator system, and while passing through the radiator system, it drives its cold in a stable thermal exchange.
This airflow is already drawn by the suction fans from the room to cool the evaporator coils to a certain extent. The evaporator is one of the internal parts of the air conditioner whose dirt has a negative effect on the thermal exchange and is due to the completely reason for the air conditioner. The evaporator coils are made using copper pipes to speed up heat exchanging with warm air flow and cool the air faster.
Condenser
Condenser is one of the internal parts of the air conditioner mounted on the external unit. This piece is made of copper tube network on an aluminum plate and is supposed to deliver refrigerant gas from the compressor system and convert it to liquid by crossing copper coils.

The air conditioner condenser is actually an interface system for converting high compressor gas flow to refrigerant liquid. The compressor gas from the compressor in the copper coil loses its heat to re -enable the fluid to continue the route for heat exchange. The condenser is one of the main interior parts of the air conditioner that is fully effective in its performance in optimal conditions.
Expansion valve in the gas cooler system
Expansion valve is another interior component of the mechanical segments located between the condenser and evaporator. This valve has the task of preparing the fluid out of the condenser to enter the evaporator. In fact, the refrigerant fluid has a high heat on the condenser side and is not suitable for the input to the evaporator exchange system. So before entering the evaporator, inside the expansion valve space, which is a copper structure, finds the ideal conditions.
Expansion valve reduces the amount of refrigerant fluid pressure and cools it provides conditions for entry into the evaporator thermal exchange system. The optimal performance of this valve in the air conditioner components has a direct impact on the efficiency of the air conditioner system and must be selected according to the capacity of the system.
Air Filter in Split
Filter is one of the mechanical components in the inner panel designed to clean the air inside the air conditioner system. The polluted air, which has a lot of dust, quickly blocks the evaporator system coil. This dirty evaporator coils can also be the reason for the work of the air conditioner. To prevent this from happening, they have designed the air filter structure in the internal unit. At the same time, it is necessary to clean the air filter surface at appropriate intervals to ensure enough air circulation inside the split space.

Electric board
This board is a control section of all motor systems and automatic air conditioner performance. In this board they use control and planned microprocessor to provide optimal conditions and, of course, complete control of different parts of the system. Performance steering, errors control, adjustment of mode and operating speed, temperature control, etc. are tasks of electric cooler electrical board.
Cooler Fan
Fan is an electromechanical portion and is one of the internal components of the air conditioner composed of the electromotor section alongside the air volume blades. These fans are tasked with creating air flow on the evaporator process and producing the cold air output of the air conditioner system.
Capacitor
Another internal component of the air conditioner is effective in launching and optimizing the compressor electromotor performance. The capacitor is placed in the electrical connection of the single -phase motor to optimize its launch conditions. Single -phase engines are not capable of starting automatic launch under normal conditions and we must use the capacitor to operate.


