Behzi

Common causes of air conditioner and split duct failure

study time 1 minute

Common causes of air conditioner and split duct failure

🔹🔸Reduction of air conditioner cooling: Creation of hot wind or reduction of air conditioner cold is one of the most common failures. Pay attention to the presence of a chemical reaction in the cooler and refrigerant system, cool air is produced. If hot air is produced, it means that this system has a problem and the cause is most of the time the gas leak of the cooler. Next, the expert examines it and then repairs it.

🔹🔸 Replacing the air filter due to a dirty air filter: Among other common cases in the breakdown of splits, the air filter is dirty. Is. The air filter is a part inside the air conditioner that needs to be cleaned regularly, and neglecting it over time will lower the performance of the system and cause damage to other parts. Therefore, it is necessary to check and clean every once in a while. Changing the air filter will ensure that there is no problem in the correct operation of the device.

🔹🔸 The function of the external or external fan of the air conditioner: The external fan, which is operated outside the air conditioner, plays a role Transfers heat from the house to the outside. If this fan does not work properly, you will feel inappropriate coldness and the heat of the house will not be solved well. This causes the compressor to overheat and disrupts the cooling system.

دلایل رایج خرابی کولر گازی و داکت اسپلیت

🔹🔸 Water leakage from air conditioner: Water leakage or water leakage is one of the common events that occurs in air conditioners. Water spilling from the internal panel of the air conditioner causes the water outlet to be blocked.

🔹🔸 Forming mold on the pipes: The presence of mold in the condenser or split gas pipes indicates a reduction in size. Gas charging or dirty devices. After the device is turned off, the leakage and melting of the ice starts. Therefore, if it is still not fixed after cleaning the filter, it is better to keep the air conditioner off until the problem is solved and the air conditioner is repaired by an expert. Sudden air conditioner: Sometimes you hear sounds from the air conditioner that are unusual and prevent people from relaxing. These sounds may often come from the internal panel or the external unit of the air conditioner. All abnormal sounds can have many reasons, but most of the time, this problem occurs due to the imbalance of the cooler's external fan or its internal fan. On the other hand, the bases of the air conditioner compressor may be loose and need to be wrenched.

🔹🔸 Central ventilation system not turning on:
Sometimes it is possible that your air conditioner does not turn on. Note that the type of air conditioners and their systems may be different, for example, the repair of LG air conditioners is different from other air conditioners. Therefore, it is better to entrust the work to Kardan before taking any action! First of all, try to adjust and check the thermostat and control, after that, if this solution does not work, it is better to get advice from a specialist company such as Zarin Service.

دلایل رایج خرابی کولر گازی و داکت اسپلیت

🔹🔸 Internal panel fan not working: Internal panel fan failure is a common problem in all air conditioners. First check the air filter, if it is not blocked you can easily fix it. If you see frost and ice on the cooling coil, you should wait until the ice melts and the efficiency of the fan is determined. Otherwise, you need a major repair by an expert. So, in general, the common problems of split duct are as follows: The air conditioner does not produce cool air. gas
remote control does not work
gas air conditioner does not heat
produce a strange noise when working from the internal panel
decrease air conditioner air flow
water drop during gas air conditioner operation
water discharge during operation
Not turning on the air conditioner
Showing an error message or error code of the air conditioner as soon as it turns on
Not turning on the air conditioner and not receiving a command from the remote control of the air conditioner
Freezing of the internal panel or the evaporator of the air conditioner