Implementation of wallpaper in the sheds
There is no discussion about the implementation of wall paste in industrial structures. 2800 Standard 6 is attached. All the points we have learned so far can be observed in sheds as well. In the figure below, we can see the details of the implementation of wallpaper in the sheds, which is the forced cross-section of the middle figure. This detail is taken from the map reading article published on Sabze Sazeh website.
Implementation of wallpaper in Janpanah
The minimum height of the parapets is at least 1.2 meters according to the regulations of the fire department. According to Appendix 6 of the 2800 standard, for the seismic restraint of the parapets, the surrounding pillars of the roof should continue up to a height of 35.2 meters on the roof. /p>

The need to implement wallpaper underground
One of the main goals of applying wallpaper in buildings is to separate the wall from the structure and prevent the interaction between the walls and the components. But some engineers have a misconception and do not consider it necessary to apply wallpaper in the basement floors. may be due to the use of the basement (usually non-residential) and the absence of side damage. If we do not have a retaining wall in the basement and the level of the base of the building is considered from the foundation, the separation of the wall from the structure in cases where it continues to under the beam due to exposure they do not find, they are of double importance.
Because if separation is not observed, we will have a short column phenomenon in the columns around the wall.
Implementation of wallpaper in panel walls
According to Appendix 6 of the 2800 standard, factory panel walls that are installed as vertical strips along the wall and function like a one-way slab.
In buildings, it is allowed to use these walls as external walls and We are internal. The use of panel walls for internal and external walls in hospitals is strongly recommended. In these walls, like other walls, the goal is to restrain outside the plane and move freely inside the plane. If the height of the wall is If there is a need for a pole, a pole is used in the middle level of the wall in the outer walls and the blades. It is allowed to connect the poles to the beams; But never connect the pole to the column and use the sitting studs for the pole. In these walls, there is no need to implement end and middle reinforcement. Therefore, it can be concluded that Appendix 6 of the 2800 standard does not consider a geometric limit for restraining these walls. And all the limitations are taken into account in the bending and shear design of the wall. In panel walls, there is no need to connect between the wall and the column, and the spaces between the two must be filled with compressible materials such as moisture-proof stone wool, and on it in joinery. Use a layer of fiber mesh or rabits. Therefore, the use of connecting parts such as interrupted studs on the column is excluded.
Implementation of wallpaper in facilities
Mechanical and electrical installations must be implemented in such a way that they do not cause problems in the performance of the walls. For this reason, the coordination of engineers at the beginning of drawing and presenting the plans is a must. But sometimes it is observed that due to lack of coordination in the presentation of plans changes in them, the facilities, especially the pipes, are passed through the wall.
So, the bed bars may be cut to implement the facilities, and the proper functioning of the wall and its integrity will be lost. The important issue should be given special attention.