What should be the proper water pressure of the package?

study time 1 minute

What should be the proper water pressure of the package?

The water pressure of the package should normally be set between 1 and 2 (1.5 and 0.7 in some models) and when it is between these two numbers, it can be said that the package is working properly. But what should be done if the pressure of the package load increases or decreases?

Increasing the pressure of the package load can damage the performance of this device. To avoid problems, it is better to check the water pressure at regular intervals. In some cases, it is possible that the pressure level of the package remains at zero for a long time, and your package works, in these cases it can damage the pump or other parts of the package.

For this To be able to adjust the water pressure, it is enough to open the package drain valve in cases where the pressure was high, and in cases where the water pressure was low, we recommend opening the filling valve. The only interface between the water used and the heating water is the valve filling the package. The important point that you should pay attention to is that you should open the valve slowly, so that the air in it is removed, and be sure to turn off the package to do this, and in cases where the filling valve has problems has been done, the water pressure of the heating circuit will gradually rise without opening the filling valve and water will come out of the safety valve three times.

Proper pressure of the package in winter

One of the most important things that may occupy your mind is what the pressure of the wall package should be in winter, so that it can show its best performance. To solve this question, we must say that the pressure of the package is the same in all brands, and they follow the same standard. The most suitable pressure for the package in winter is 1.5 bar. In cases where the pressure drops below this number, this issue is displayed by error codes on the display. You can raise the pressure with the help of the valve under the device to solve these problems. We should also say about the pressure of the butane package, which should be between 1 and 2.5 bar in the cold seasons of the year. The pressure of the Lorch package in winter, which is one of the Bhutan package models, should be between 1 and 2.5 bar.

Important points about package water pressure


● The important point that you should pay attention to is that the filling valve of the device must be closed at all times. Adjust the load of the device only in cases where it is not supposed to.
● In cases where the load level is constant by opening the filler valve, this is due to the following reasons.

- In cases where the water pressure of the building is low, in these cases, you should adjust the load, so that you can increase the water pressure of the building.
- Sometimes, the manometer of your package may get clogged, in these cases, it is better is, get help from experts in this field, and prevent possible damages. 1 to 1.5 times. So, if you intend to, adjust the pressure of the package, and if your wall package is on, and its temperature is above 60 degrees Celsius. In these cases, you should set the pressure of the package to 1.5 bar. When it is supposed to do this, if the package is off, and the device is cold, and the temperature is less than 60, you should set the package pressure to 1 bar. Maybe you have a question about the reason for doing this? In this case, we must say that when the package is cold, when you turn on the package to start working, after a certain period of time, the package heats up, and the reason for this is due to the expansion of water, which It increases water pressure.

What is the reason for the increase in package pressure?


● One of the reasons that can cause the pressure of the package to rise is because the people who use the package cannot properly adjust the load pressure.
● When that the temperature of the device increases, and the pressure decreases. This issue happens after the package cools down, which is caused by the failure of the expansion source or lack of air. ● It is possible that the pressure of the package increases due to the failure of the filling valve of the package. >

فشار مناسب آب پکیج چه مقدار باید باشد؟
Can increasing package pressure be dangerous?

To answer this question, we must say that all the parts used in package production cannot withstand high pressure for a long time. This issue can cause problems for you. But in order to avoid this problem, the packages are placed on the circuit of the system, so that when the pressure of the load increases, it starts draining the excess water. The part that is responsible for doing this work is the assurance valve (triple valve).

Increasing and decreasing package water pressure

Sometimes, your package may suffer from pressure drop due to various issues. You can solve the problem by doing the necessary investigation. To find the source of the problem, just do the following.

In the first step, you should check the filling valve of the package, and if you see that the valve is open, you should close it. The appropriate number for the normal package pressure should be between 0.7 and 2. In cases where you see that the water pressure is higher or lower than this number, you should fix the problem. The problems that arise for the package are shown by the error code on the package display. In cases where it is determined that the reason for the pressure drop in the package is due to a broken filling valve, you should seek help from a repairman to solve the problem. After doing the necessary checks, the repairmen should repair or replace it.