Welding machines are widely used in the production of industrial parts and connecting them to each other. By using welding devices, a permanent connection is made between the parts and it is no longer possible to separate them. There are different types of welding machines, each of which is used for its unique applications and features. Meanwhile, the inverter welding machine has attracted a lot of attention. Welding inverters are a new generation of welding devices, some of which work with alternating current and others with both alternating and direct current.
5 Causes of the Usage of Inverter Welding Machine
Damage or disconnection of the plug and cable of the welding machine Failure to connect the key of the device or melting of the platinum bases of the device Extensive breakdown of the welding machine's amplifier amp
Solution: First turn off the power and then check the cable and plug of the welding machine. If you find any damage or failure in them, you should repair or replace them. Then connect the power and turn on the welding machine. If the welding machine turns on, it means the problem is solved.
Another factor that may cause the inverter welding machine to not turn on, failure to connect the machine key or melting Its bases are platinum. This issue may occur due to high pressure and high temperature.
Solution:
First turn off the power and then open the switch of the welding machine. If you find that the device key is not connected or its platinum pins are melted, you need to repair or replace the device key. Then connect the electricity and turn on the welding machine.
The main power part of the device includes a transformer, diode, capacitor and resistor, which has the task of converting city electricity to the electricity required by the device. This part may be damaged due to surge, high heat, impact or burn.
Solution:
First cut off the power and then open the main power part of the welding machine. If you find that the parts of the main power part of the device are damaged or burned, you must repair or replace them. Then connect the power and turn on the welding machine. If the welding machine turns on, it means the problem is solved.
Inverter welding machine needs a certain voltage to work, which is called "biasing voltage". This voltage makes the transistors of the welding machine work properly and regulate the output current of the machine. Biasing feeding system is a part of the welding machine that produces and maintains this voltage. If this part is damaged, the welding machine does not turn on or has poor performance. The reason for the failure of the biasing power system may be due to high heat, surge and impact.
Solution:
To solve this problem, you need to open the biasing power supply system section. If its parts were broken, you should repair or replace them.
Another factor that may cause the inverter welding machine not to turn on is the extensive failure of the amp amplification part of the machine. The amplification part of the amp consists of transistor, diode, capacitor and resistance, which is responsible for amplifying the output current of the device. This part may be damaged due to high heat, surge, impact or burn.
Solution:
If the amplifier part of the device is broken or burnt, you need to repair or replace them. To do this, you can get help from IP Emdad experts.