Why is the hospital elevator standard so different and strict?

A hospital elevator is not just an oversized passenger elevator. Fundamental differences in usage make this type of elevator a completely separate category. The requirements of the hospital elevator standard have been developed considering the following scenarios:

  1. Transporting the patient: Transferring patients on a bed or stretcher should be done without any jolts, vibrations or sudden stops. Any unexpected movement can worsen the condition of the critically ill patient.
  2. Emergency conditions: In the event of an emergency code (Code Blue), the hospital elevator must be provided to the resuscitation team as quickly as possible without stopping to reach the patient.
  3. Hygiene and infection control: Environment The hospital is susceptible to contamination. The hospital elevator standard gives particular importance to washable, antibacterial materials and proper ventilation systems.
  4. Carrying heavy equipment: These elevators must have the ability to carry heavy and sensitive medical equipment such as mobile radiology devices, surgical beds, etc.
  5. 24/7 operation: an elevator A hospital should be available 24/7 without interruption. The breakdown of this elevator can disrupt the operation of the entire hospital.

Esman Burj Ofoq Sky Elevator Company, fully understanding this heavy responsibility, executes all its hospital elevator projects with the highest level of precision and commitment to the hospital elevator standard.

Key requirements in the hospital elevator standard (EN 81-70 and the national standard of Iran)

National and international standards, especially the European standard EN 81-70, which deals with accessibility for disabled people, define the main design framework of a hospital elevator. In the following, we will examine the most important requirements that are carefully observed by Asman Burj Ofog.

1. Dimensions and capacity of the hospital elevator cabin

The most important characteristic of a hospital elevator is its dimensions. The hospital elevator standard specifies the minimum dimensions for the comfortable placement of a hospital bed with several medical staff and associated equipment.

  • Minimum useful dimensions of the cabin: 140 cm wide and 240 cm deep are usually considered as the minimum dimensions for a standard bed lift. This space allows the maneuvering of the bed.
  • Door opening width: The minimum door opening width should be 110 cm so that the hospital bed can enter and exit easily without collision.
  • Capacity: The capacity of these elevators usually starts from 1600 kg (21 people) and can be more depending on the needs of the treatment center. Asman Burj Ofoq offers the most optimal capacity by analyzing the traffic and needs of the hospital.

2. Smooth Ride

Hospital elevator standard has a special emphasis on the quality of movement. To achieve this goal, advanced technologies are used:

  • VVVF (Variable Voltage Variable Frequency) system: By precisely controlling the voltage and frequency of the motor, this system creates a very smooth start, acceleration, deceleration and stop and eliminates any movement shock.
  • Precise leveling Accuracy): Hospital elevator must stop with millimeter accuracy at floor level (usually with an error of less than ±5 mm). The presence of any level difference between the cabin floor and the floor can be dangerous when moving the bed. We guarantee this accuracy at Asman Burj Ofoq by using advanced sensors.

3. Safety and emergency features

The safety system of a hospital elevator must be perfect.

  • Emergency Power System (UPS or Generator): In the event of a city power outage, the hospital elevator standard requires the elevator to reach the nearest floor and open its doors. In more advanced models, the elevator continues to work using a generator.
  • Fireman Mode: During a fire, the elevator comes to the main floor and is available only to firefighters.
  • Emergency Code Mode (Code Blue Mode): This is a vital feature in It is a hospital elevator. By activating this mode by the treatment staff, the elevator cancels all other summons and goes directly to the destination floor without stopping. Asman Burj Ofoq implements this feature as a custom on the control panel of hospital elevators.

4. Hygiene and interior materials of the cabin

Infection control is a priority. For this reason, hospital elevator standard pays special attention to the interior details of the cabin:

  • Flooring: Use of antibacterial, seamless, washable flooring (such as hospital-grade PVC sheets) is required.
  • Walls and ceiling: Walls should be made of stainless steel (preferably grade 304 or higher, which is resistant to disinfectants) or coated sheets. be made antibacterial. The design should be such that the corners and corners are easily accessible for cleaning.
  • Ventilation system: Having a strong ventilation system is essential for air circulation and preventing the accumulation of pollution. The use of HEPA filters can also be considered as an option.

Esman Burj Ofoq Company fully aware of these requirements, proposes and implements the best materials for the construction of your hospital elevator cabin.

5. Accessibility for all

The

hospital lift standard (in accordance with EN 81-70) requires that the lift be optimal for use by the disabled, the elderly and the blind:

  • Control panel: The buttons should be installed at a suitable height and have Braille lines.
  • Voice floor announcement: The speaker system should announce the floor number and the direction of movement.
  • Mirror on the end wall: The presence of a mirror helps wheelchair users to exit without turning around. to see the back of the cabin.
  • Handrail: It is necessary to install a handrail on at least one of the cabin walls to maintain people's balance.

The role of Aseman Borj Ofoq company in realizing the hospital elevator standard

We at Asman Burj Ofog believe that the implementation of a successful hospital elevator project is the result of a combination of precise engineering, supply of high-quality parts and perfect execution.

  1. Expert consultation and design: The first step is to understand the unique needs of each treatment center. By visiting the site and holding meetings with the management and technical team of the hospital, our experts present a plan that fully meets the requirements of the hospital elevator standard and the operational needs of that center.
  2. Supplying parts from reputable brands: We have low-noise gearless motors, smart control panels with the ability to program emergency mode, and automatic doors with smooth and fast operation. We use the best European and Iranian brands. The quality of the parts guarantees the stable performance of your hospital elevator.
  3. Installation by an expert team: The technical team of Asman Burj Ofog consists of trained and experienced technicians who are familiar with all the details and nuances of installing a hospital elevator. Careful supervision at all stages, from forging to final commissioning, ensures the quality of our work.
  4. Service and preventive maintenance: A hospital elevator cannot wait for failure. By providing special service and maintenance contracts for medical centers, we periodically and regularly review, adjust and replace all parts if necessary to prevent any interruption in the operation of the elevator. Our quick response team is also ready to serve 24 hours a day in Gilan province (Rasht, Anzali, etc.).

Conclusion: A choice for health and safety

Hospital lift (bed lifter) is a vital investment for any medical center that is directly related to human life and health. Strict compliance with the Hospital Elevator Standard is not a choice, but a non-negotiable requirement. These standards, from the dimensions of the cabin to the type of material and emergency capabilities, are all designed with one goal: to create a safe, reliable and efficient environment for moving patients and medical staff.

A.B.O Elevator Company proudly announces that relying on technical knowledge, successful experience and commitment to quality, it is ready to be your trusted partner in the design, installation and maintenance of hospital elevators according to the highest level of standards. If you are looking for a perfect solution for your treatment center, contact us today so that our experts can guide you in this important direction.

Mehtab Qolipur

Mehtab Qolipur

Post Author

5352

common:article

View Page

I provide specialized article writing and content creation services for websites. By writing SEO-oriented content, I help to improve the ranking of the site in Google, increase visits and attract target audiences, and I produce accurate, practical and suitable content for businesses.

Similar Posts






  • Why is the hospital elevator standard so different and strict?

  • Key requirements in the hospital elevator standard (EN 81-70 and the national standard of Iran)

  • The role of Aseman Borj Ofoq company in realizing the hospital elevator standard