Types of package service
There are two types of service packages, which include full service and periodical service. In the full package service, all parts must be checked one by one so that if there are any problems, they can be fixed before they need repair. But in the periodic service that takes place twice a year, once before the start of the cold season and once after it ends, the parts are checked and their defects are fixed.
But in general, the wall package service that must be done by a professional service includes the following:
Descaling
It is recommended to use polyphosphate sediment traps to descale the wall package. Also, there should be proper ventilation during descaling. If descaling is not done on time, the device will face various problems such as water pressure reduction and consumption water not being heated, which can cause great damage to this heating system and reduce its lifespan. In this regard, we invite you to watch the following clip to learn how to wash the radiator circuit and the package in order to remove deposits inside the circuit.
Water pressure control A service worker must also control the water pressure when servicing the package, because if the water pressure entering the device is high or low, it can damage the internal parts of the package and disable the device. In the clip below, Mr. Saleh Abadi has provided more explanations about the effect of low water pressure in the building on the performance of the package and how to solve this problem.
Controlling the operation of two heating and sanitary circuits
The package servicer must ensure the correct operation of these two circuits during the service of the device. Releasing the axis of the circulation pumpAdjusting the gas valve
It should be noted that checking the gas valve of the heating system and resetting its bolts and nuts is a specialized work that if not entrusted to the repairman of the package, it can cause pressure cause gas problems. In addition, if a suitable strainer is placed on the gas valve during the service of this part of the package, it can increase the life of this valve. Heat adjustment
With the help of limit switches and thermostatic valve on the heating radiator, you can adjust and provide the required heat of the environment so that it is not too hot or too cold.
Checking the function of the chimney or package fan
If your package has a fan, you must check it. But if you have a package without a fan, you need to check the chimney paths to make sure they are not blocked. For this purpose, it is enough to throw a small object into the chimney. If this object passes through the chimney, it means that its path is open. Keep in mind that chimneys should not have many twists and turns, and a separate chimney should be used for each device. So, since the use of an improper chimney leads to the risk of choking and silent death, it must be done with the help of an expert.
Package and radiator ventilation
Package and radiator ventilation improves the heating efficiency of the device and radiator blocks, reduces the risk of water leakage, reduces noise and possible damage. To the device, the optimal use of gas and reducing its costs. The best time to ventilate is after the radiators are hot, of course, the package service worker must be careful not to injure himself with the hot heating water.